EUVIMEDEUVIMED entdecken
Open Access

In vivo reproducibility of 3D relayed NOE in the healthy human brain at 7 T

Blake Benyard iD, Ravi Prakash Reddy Nanga iD, Neil E Wilson, Deepa Thakuri, Paul S Jacobs iD, Anshuman Swain, Dushyant Kumar iD, Ravinder Reddy iD

Magnetic Resonance in Medicine · 2023

DOI: 10.1002/mrm.29600 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2023. Verfasst von Blake Benyard und 7 weiteren Autor:innen. Beteiligte Einrichtung: Center for Metabolic Imaging in Precision Medicine (CAMIPM), Department of Radiology, Perelman School of Medicine at the University of Pennsylvania, …. Hauptthemen laut MEDLINE: Algorithms, Brain Neoplasms. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, NIA NIH HHS, National Institute of Biomedical Imaging and Bioengineering.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Nuclear Overhauser effect (NOE) is based on dipolar cross‐relaxation mechanism that enables the indirect detection of aliphatic protons via the water proton signal. This work focuses on determining the reproducibility of NOE magnetization transfer ratio (NOE MTR ) and isolated or relayed NOE (rNOE) contributions to the NOE MRI of the healthy human brain at 7 Tesla (T).

Methods

We optimized the amplitude and length of the saturation pulse by acquiring NOE images with different values with multiple saturation lengths. Repeated NOE MRI measurements were made on five healthy volunteers by using optimized saturation pulse parameters including correction of B 0 and inhomogeneities. To isolate the individual contributions from z‐spectra, we have fit the NOE z‐spectra using multiple Lorentzians and calculated the total contribution from each pool contributing to the overall NOE MTR contrast.

Results

We found that a saturation amplitude of 0.72 μT and a length of 3 s provided the highest contrast. We found that the mean NOE MTR value in gray matter (GM) was 26%, and in white matter (WM) was 33.3% across the 3D slab of the brain. The mean rNOE contributions from GM and WM values were 8.9% and 9.6%, which were ∼10% of the corresponding total NOE MTR signal. The intersubject coefficient of variations (CoVs) of NOE MTR from GM and WM were 4.5% and 6.5%, respectively, whereas the CoVs of rNOE were 4.8% and 5.6%, respectively. The intrasubject CoVs of the NOE MTR range was 2.1%–4.2%, and rNOE range was 2.9%–10.5%.

Conclusion

This work has demonstrated an excellent reproducibility of both inter‐ and intrasubject NOE MTR and rNOE metrics in healthy human brains at 7 T.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlgorithmsBrain NeoplasmsHumansReproducibility of ResultsImage Interpretation, Computer-AssistedBrainMagnetic Resonance ImagingProtons

Stichwörter der Autor:innen

CESTMTRNOEbraincross-relaxationrNOE

Substanzen

Protons

Autor:innen und Institutionen

  • Center for Metabolic Imaging in Precision Medicine (CAMIPM), Department of Radiology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA.

ORCID-Profile: Blake Benyard, Ravi Prakash Reddy Nanga, Paul S Jacobs, Dushyant Kumar, Ravinder Reddy

Förderung

  • NIBIB NIH HHS
  • NIA NIH HHS
  • National Institute of Biomedical Imaging and Bioengineering

Zitieren

APA

Benyard, B., Nanga, R. P. R., Wilson, N. E., Thakuri, D., Jacobs, P. S., Swain, A., Kumar, D., & Reddy, R. (2023). In vivo reproducibility of 3D relayed NOE in the healthy human brain at 7 T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29600

Vancouver

Benyard B, Nanga RPR, Wilson NE, Thakuri D, Jacobs PS, Swain A, et al. In vivo reproducibility of 3D relayed NOE in the healthy human brain at 7 T. Magnetic Resonance in Medicine. 2023. doi:10.1002/mrm.29600

BibTeX
@article{Benyard2023,
  author = {Benyard, Blake and Nanga, Ravi Prakash Reddy and Wilson, Neil E and Thakuri, Deepa and Jacobs, Paul S and Swain, Anshuman and Kumar, Dushyant and Reddy, Ravinder},
  title = {In vivo reproducibility of 3D relayed NOE in the healthy human brain at 7 T},
  journal = {Magnetic Resonance in Medicine},
  year = {2023},
  doi = {10.1002/mrm.29600}
}
Kostenlos starten →