Development of a morphologically realistic mouse phantom for pre‐clinical photoacoustic imaging
Medical Physics · 2023
DOI: 10.1002/mp.16651 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, 2023. Verfasst von Valeria Grasso und 4 weiteren Autor:innen. Beteiligte Einrichtung: FUJIFILM VisualSonics, Amsterdam, The Netherlands. Hauptthemen laut MEDLINE: Photoacoustic Techniques. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 53 Literaturangaben. Gefördert von: European Union's Horizon 2020 research and innovation program under the Marie Skłodowska-Curie, EPSRC-ThUNDDAR network, Academy of Medical Sciences Springboard.
Abstract (Originalsprache)
Background
Characterizations based on anatomically realistic phantoms are highly effective to perform accurate technical validation of imaging systems. Specifically for photoacoustic imaging (PAI), although a variety of phantom models with simplified geometries are reported, an unmet need still exists to establish morphologically realistic heterogeneous pre‐clinical phantoms. So the development of a mouse‐mimicking phantom can reduce the use of animals for the validation and standardization studies of pre‐clinical PAI systems and thus eventually translate the PAI technology to clinical research.
Purpose
Here we designed, developed, and fabricated a stable phantom that mimics the detailed morphology of a mouse, to be used as a realistic tool for PAI.
Methods
The mouse phantom, has been designed by using a combination of image modeling and 3D‐printing techniques. As a tissue‐mimicking material, we have used copolymer‐in‐oil‐based material that was recently proposed by the International Photoacoustic Standardization Consortium (IPASC). In particular, the anatomically realistic phantom has been modeled by using the real atlas of a mouse as a reference. The mouse phantom includes a 3D‐printed skeleton and the main abdominal organs such as the liver, spleen, and kidneys obtained by using doped copolymer‐in‐oil material with 3D‐printed molds. In addition, the acoustic and optical properties of the tissue‐mimicking material and the long‐term stability have been broadly characterized.
Results
Furthermore, our studies showed that the phantom is durable and stable for more than 200 days, under normal storage and repeated use. Fabrication protocol is easy to reproduce. As a result, the proposed morphologically realistic mouse phantom offers durability, material compatibility, and an unprecedented realistic resemblance to the actual rodents’ anatomy in PAI.
Conclusion
This durable morphologically realistic mouse phantom would minimize the animal experiments in compliance with the 3R principle of Replacement, Reduction, and Refinement. To our knowledge, this is the first time an anatomically realistic heterogeneous mouse phantom has been proposed for PAI in pre‐clinical animal imaging and tested its durability over 200 days.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- FUJIFILM VisualSonics, Amsterdam, The Netherlands.
- Institute for Materials Science, Faculty of Engineering, Christian-Albrecht University of Kiel, Kiel, Germany.
- Department of Engineering Science, University of Oxford, Oxford, UK.
- Institute of Materials Research, Division Metallic Biomaterials, Helmholtz-Zentrum Hereon GmbH, Geesthacht, Germany.
- School of Science and Engineering, University of Dundee, Dundee, UK.
- Centre for Medical Engineering and Technology, University of Dundee, Dundee, UK.
Förderung
- European Union's Horizon 2020 research and innovation program under the Marie Skłodowska-Curie
- EPSRC-ThUNDDAR network
- Academy of Medical Sciences Springboard
Zitieren
APA
Grasso, V., Raymond, J. L., Willumeit-Römer, R., Joseph, J., & Jose, J. (2023). Development of a morphologically realistic mouse phantom for pre‐clinical photoacoustic imaging. Medical Physics. https://doi.org/10.1002/mp.16651
Vancouver
Grasso V, Raymond JL, Willumeit-Römer R, Joseph J, Jose J. Development of a morphologically realistic mouse phantom for pre‐clinical photoacoustic imaging. Medical Physics. 2023. doi:10.1002/mp.16651
BibTeX
@article{Grasso2023,
author = {Grasso, Valeria and Raymond, Jason L and Willumeit-Römer, Regine and Joseph, James and Jose, Jithin},
title = {Development of a morphologically realistic mouse phantom for pre‐clinical photoacoustic imaging},
journal = {Medical Physics},
year = {2023},
doi = {10.1002/mp.16651}
}
EUVIMED