EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Proximal anatomical axes show bidirectional variability: Accurate tibial slope requires mechanical axis measurement

Barbara C. Boer, Quinten W. T. Veerman, Reinoud W. Brouwer, Judith olde Heuvel, Tony G. van Tienen, Wolf Petersen, Roy A. G. Hoogeslag

Knee Surgery, Sports Traumatology, Arthroscopy · 2026-12 · 34 (10) · 3575-3585

DOI: 10.1002/ksa.70093 ↗
AbstractBibliografische Angaben

Abstract

Abstract Purpose To determine whether posterior tibial slope (PTS) measured to proximal anatomical axes can serve as a reliable proxy for PTS measured to the mechanical tibial axis (mTA). Methods In patients ≥18 years with failed anterior cruciate ligament reconstruction, medial and lateral PTS were measured relative to the mTA on a lateral lower‐leg radiograph, and relative to the proximal tibial anatomical axis (PTAA), anterior tibial cortical axis (ATC) and posterior tibial cortical axis (PTC) on a lateral knee radiograph. Agreement was assessed using correlation coefficients, measurement error and Bland–Altman analysis. Diagnostic accuracy of the conventional ≥12° PTAA‐based PTS cut‐off for slope‐reducing osteotomy was determined. Results Fifty‐nine knees were analyzed. Correlation between proximal anatomical axes and mTA‐based PTS measurements was strong ( r ≥ 0.71), but agreement was poor. Mean measurement error for PTAA was 0.1 ± 2.4° (range: −5.7° to 7.6°) and −0.5 ± 2.4° (range: −6.6° to 5.2°), for ATC −3.4 ± 2.6° (range: −8.6° to 5.9°) and −3.7 ± 2.6° (range: −9.9° to 2.7°) and for PTC 3.0 ± 2.6° (range: −2.9° to 10.4°) and 2.7 ± 2.4° (range: −3.6° to 7.8°) for the medial and lateral plateau, respectively. For PTAA, absolute measurement error ≥2° occurred in approximately 50% of knees. Bland–Altman analysis showed 95% levels of agreement ranging from −4.89° to 4.62° (medial) and −5.11° to 4.11° (lateral). Using the ≥12° cut‐off on PTAA‐based PTS values misclassified approximately one in three knees (19.5% false‐positive and 13.2% false‐negative) relative to the mTA‐based PTS reference values. Conclusion Despite strong correlation, proximal anatomical axes‐based PTS measurements on routine lateral knee radiographs show substantial, bidirectional measurement error outside clinically acceptable limits of agreement compared to mTA‐based PTS measurements on full‐length lateral lower‐leg radiographs. Single‐exposure, full‐length lateral lower‐leg radiographs should be obtained to measure PTS relative to the mTA when considering slope‐reducing osteotomy. Level of Evidence Level IV.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →