EUVIMEDEUVIMED entdecken
Systematische ÜbersichtOpen Access · CC BY 4.0

Metal sensitivity in total joint arthroplasty: None of the current diagnostic tests are reliable, sensitive and specific enough to guide treatment decisions!

Umile Giuseppe Longo iD, Giovanni Intermesoli, Raffaele Di Tommaso, Alberto Lalli iD, Bruno Violante, Michael T Hirschmann iD

Knee Surgery, Sports Traumatology, Arthroscopy · 2025

DOI: 10.1002/ksa.12706 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2025. Verfasst von Umile Giuseppe Longo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Fondazione Policlinico Universitario Campus Bio-Medico, Rome, Italy. Hauptthemen laut MEDLINE: Metals, Hypersensitivity, Nickel, Arthroplasty, Replacement. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This systematic review was conducted to evaluate the current literature on metal hypersensitivity in patients undergoing joint arthroplasty. The aims of the study were to report diagnostic tools used to assess metal hypersensitivity and to report complications arising in patients who are hypersensitive to nickel or other metals performing joint arthroplasty. Given the potential impact on implant longevity and patient outcomes, understanding the clinical relevance of metal hypersensitivity is crucial for optimising surgical decision‐making.

Methods

This systematic review adheres to PRISMA guidelines and evaluates the variability in diagnostic approaches and the challenges in clinical management. Included in this review were studies involving patients sensitive to nickel or other metals undergoing joint arthroplasty. Eligibility criteria focused on commonly employed diagnostic tools and associated complications. A comprehensive literature search was conducted across Medline, EMBASE, Scopus, CINAHL, and CENTRAL databases. The methodological quality of the included studies was assessed using the Joanna Briggs Institute Critical Appraisal tool for case series and the ROBINS‐I tool for case‐control studies.

Results

Twenty‐four articles met the inclusion criteria and were included in this systematic review. A total of 4865 patients undergoing joint arthroplasty were selected. Diagnostic tools included patch testing, lymphocyte transformation test (LTT), and medical history assessment. Variability in time point of testing and diagnostic protocols was noted. Complications including joint pain, swelling, reduced range of motion, and implant failure were reported in 12 studies. Clinical outcomes varied widely: some studies showing no significant differences between hypersensitive and non‐hypersensitive patients, while others reported increased pain and reduced joint function.

Conclusion

There is a lack of a standardised protocol for diagnosing metal hypersensitivity, leading to uncertainty regarding test selection and timing. This inconsistency leads to variability in reported outcomes, with limited studies focusing on post‐surgical hypersensitivity in patients. Level of Evidence Level III, systematic review.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MetalsHypersensitivityNickelArthroplasty, ReplacementHumansPatch TestsClinical Decision-MakingPostoperative ComplicationsArthroplasty, Replacement, HipHip Prosthesis

Stichwörter der Autor:innen

allergyhypersensitivityjoint arthroplastymetalsnickelnickel‐free

Substanzen

MetalsNickel

Autor:innen und Institutionen

  • Fondazione Policlinico Universitario Campus Bio-Medico, Rome, Italy.
  • Orthopaedic Department, Clinical Institute Sant'Ambrogio, IRCCS - Galeazzi, Milan, Italy.
  • Department of Orthopedic Surgery and Traumatology, Kantonsspital Baselland, Bruderholz, Switzerland.
  • Department of Clinical Research, Research Group Michael T. Hirschmann, Regenerative Medicine & Biomechanics, University of Basel, Basel, Switzerland.

ORCID-Profile: Umile Giuseppe Longo, Alberto Lalli, Michael T Hirschmann

Zitieren

APA

Longo, U. G., Intermesoli, G., Di Tommaso, R., Lalli, A., Violante, B., & Hirschmann, M. T. (2025). Metal sensitivity in total joint arthroplasty: None of the current diagnostic tests are reliable, sensitive and specific enough to guide treatment decisions!. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.12706

Vancouver

Longo UG, Intermesoli G, Di Tommaso R, Lalli A, Violante B, Hirschmann MT. Metal sensitivity in total joint arthroplasty: None of the current diagnostic tests are reliable, sensitive and specific enough to guide treatment decisions!. Knee Surgery, Sports Traumatology, Arthroscopy. 2025. doi:10.1002/ksa.12706

BibTeX
@article{Longo2025,
  author = {Longo, Umile Giuseppe and Intermesoli, Giovanni and Di Tommaso, Raffaele and Lalli, Alberto and Violante, Bruno and Hirschmann, Michael T},
  title = {Metal sensitivity in total joint arthroplasty: None of the current diagnostic tests are reliable, sensitive and specific enough to guide treatment decisions!},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2025},
  doi = {10.1002/ksa.12706}
}
Kostenlos starten →