EUVIMEDEUVIMED entdecken
Crossref

Accurate determination of hip implant wear, cup anteversion and inclination through AI automated 2D‐3D registration

Stefan Klebingat, Tanja Bien iD, Janine Hürtgen iD, Priyanka Grover, Marcel Dreischarf, Shareef Alkhateeb, Marcus Jäger, Georg Rose

Journal of Orthopaedic Research · 2023-09 · 41 (9) · 1985-1995

DOI: 10.1002/jor.25538 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Orthopaedic Research, online erschienen am 05.03.2023. Verfasst von Stefan Klebingat und 7 weiteren Autor:innen. Beteiligte Einrichtung: University Clinic for Neuroradiology, University Hospital Magdeburg, University Clinic for Neuroradiology, Magdeburg, Germany. Hauptthemen laut MEDLINE: Hip Prosthesis, Arthroplasty, Replacement, Hip. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 53 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The precise and accurate measurement of implant wear, acetabular cup anteversion and inclination from routine anterior‐posterior radiographs still poses a challenge. Current approaches suffer from time‐consuming procedures accompanied by low and observer‐dependent accuracy and precision. We present and validate a novel, automated method for determining total hip arthroplasty parameters by comparing its accuracy and precision with methods in contemporary scientific literature. The algorithm uses CAD‐model‐based two dimensional‐three dimensional (2D‐3D)‐registration supported by convolutional neural networks. Two in‐vitro experimental set‐ups were designed to validate the proposed 2D‐3D‐method. The set‐ups provided 84 predefined wear values and 24 configurations of anteversion and inclination in 114 radiographs. Accuracy and precision were evaluated by systematically comparing the predefined ground truth and the automatically calculated values from in‐vitro X‐rays. In addition, an algorithm was developed and validated against physician's measurements on clinical X‐rays to determine the inclination of the interteardrop (ITL) and biischial line (BL) to account for the individual patient's pelvic rotation in the frontal plane. Using X‐rays from experimental set‐ups, the determined mean error was 0.014 mm (standard deviation: 0.020 mm; root‐mean‐square‐error: 0.024 mm) for wear in pelvic position, −0.01° (0.24°; 0.23°) for radiographic cup anteversion, and 0.11° (0.38°; 0.39°) for radiographic cup inclination. The inclination of ITL and BL was automatically determined in all clinical X‐rays with excellent interclass correlation coefficients of 0.95 and 0.91, respectively. The presented algorithm allows the accurate and precise evaluation of total hip arthroplasty parameters without additional equipment. The method might help to investigate different implant designs, biomaterials, and surgical techniques with greater objectivity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hip ProsthesisArthroplasty, Replacement, HipHumansTomography, X-Ray ComputedAcetabulumArtificial Intelligence

Stichwörter der Autor:innen

anteversion and inclinationarthroplasty-hipartificial intellligencediagnostic imagingimplant wear

Autor:innen und Institutionen

  • University Clinic for Neuroradiology, University Hospital Magdeburg, University Clinic for Neuroradiology, Magdeburg, Germany.
  • RAYLYTIC GmbH, Department of Research & Development, Leipzig, Germany.
  • Department of Orthopaedics, Trauma and Reconstructive Surgery, St. Marien-Hospital, Mülheim an der Ruhr, Germany.
  • Healthcare Telematics and Medical Engineering, Institute of Medical Engineering and Research Campus STIMULATE, Otto von Guericke University Magdeburg, Magdeburg, Germany.

ORCID-Profile: Tanja Bien, Janine Hürtgen

Zitieren

APA

Klebingat, S., Bien, T., Hürtgen, J., Grover, P., Dreischarf, M., Alkhateeb, S., Jäger, M., & Rose, G. (2023). Accurate determination of hip implant wear, cup anteversion and inclination through AI automated 2D‐3D registration. Journal of Orthopaedic Research, 41(9), 1985-1995. https://doi.org/10.1002/jor.25538

Vancouver

Klebingat S, Bien T, Hürtgen J, Grover P, Dreischarf M, Alkhateeb S, et al. Accurate determination of hip implant wear, cup anteversion and inclination through AI automated 2D‐3D registration. Journal of Orthopaedic Research. 2023;41(9):1985-1995. doi:10.1002/jor.25538

BibTeX
@article{Klebingat2023,
  author = {Klebingat, Stefan and Bien, Tanja and Hürtgen, Janine and Grover, Priyanka and Dreischarf, Marcel and Alkhateeb, Shareef and Jäger, Marcus and Rose, Georg},
  title = {Accurate determination of hip implant wear, cup anteversion and inclination through AI automated 2D‐3D registration},
  journal = {Journal of Orthopaedic Research},
  year = {2023},
  volume = {41},
  number = {9},
  pages = {1985--1995},
  doi = {10.1002/jor.25538}
}
Kostenlos starten →