Automated and Fully Validated High‐Throughput LC‐MS/MS Assay for Analyzing Multiple Drugs of Abuse in Oral Fluids Using Novel Features in Sample Preparation and Chromatographic Conditions
Journal of Mass Spectrometry · 2025-05 · 60 (5)
DOI: 10.1002/jms.5132 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Mass Spectrometry, online erschienen am 08.04.2025. Verfasst von Joakim Tan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Pharmacology, Laboratory of Drugs of Abuse Analysis, Karolinska University Hospital, Stockholm, Sweden. Hauptthemen laut MEDLINE: High-Throughput Screening Assays, Illicit Drugs, Saliva, Substance Abuse Detection. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Oral fluid sampling offers advantages over other biological matrices, mainly due to its noninvasive procedure avoiding privacy intrusion. The fully automated sample preparation procedure is based on salting‐out assisted liquid–liquid extraction (SALLE) combined with high‐efficiency LC‐MS/MS methods for both screening and confirmation of 37 drugs and incorporates novel features enabling direct injection of acetonitrile extracts into an innovative chromatographic system. The methods' drug panel includes opioids, benzodiazepines, benzodiazepine‐like drugs, cannabinoids, and stimulants. A full method validation was performed using OF/buffer from Greiner Bio‐ONE International and Quantisal saliva collection devices. The validation included assessments of linearity, sensitivity, precision, accuracy, extraction recovery, matrix effects, process efficiency, stability, and carryover. All compounds demonstrated linearity across the concentration range 1–25 ng/mL, with R 2 ≥ 0.99. Both methods' limit of detection ranged between 0.001 and 0.03 ng/mL, and the limit of quantification ranged between 0.02 and 0.09 ng/mL. Precision was ≤ 14.8% for screening and ≤ 8.5% for the confirmation method. Accuracy was ± 13.6% for screening and ± 8.7% (except at 0.5 and 1 ng/mL, where it was ± 25.3% and ± 17.6%, respectively) for the confirmation method. Extraction recoveries ranged from 40.0% to 95.1%, except for hydromorphone (27.4%) and morphine (34.4%). Although matrix effects were observed for a large number of compounds to varying degrees, they were largely compensated for by the use of deuterium‐ and 13 C‐labeled internal standards (IS). IS‐corrected overall process efficiency ranged from 100.7% to 119.1% with precision (CV%) ≤ 10.8% for all compounds. Spiked calibrators and QC samples in OF were stable in autosampler for up to 72 h and in the freezer for 3 days. Methanol working solutions were stable for 6 months. No significant carryover was observed. The methods have been successfully implemented in the routine analysis of approximately > 1000 samples per month since March 2024.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Clinical Pharmacology, Laboratory of Drugs of Abuse Analysis, Karolinska University Hospital, Stockholm, Sweden.
- Karolinska Institute, Stockholm, Sweden.
ORCID-Profile: Niclas Nikolai Stephanson
Zitieren
APA
Tan, J., Rylski, A., Bergqvist, A., & Stephanson, N. N. (2025). Automated and Fully Validated High‐Throughput LC‐MS/MS Assay for Analyzing Multiple Drugs of Abuse in Oral Fluids Using Novel Features in Sample Preparation and Chromatographic Conditions. Journal of Mass Spectrometry, 60(5). https://doi.org/10.1002/jms.5132
Vancouver
Tan J, Rylski A, Bergqvist A, Stephanson NN. Automated and Fully Validated High‐Throughput LC‐MS/MS Assay for Analyzing Multiple Drugs of Abuse in Oral Fluids Using Novel Features in Sample Preparation and Chromatographic Conditions. Journal of Mass Spectrometry. 2025;60(5). doi:10.1002/jms.5132
BibTeX
@article{Tan2025,
author = {Tan, Joakim and Rylski, Alexia and Bergqvist, Anders and Stephanson, Niclas Nikolai},
title = {Automated and Fully Validated High‐Throughput LC‐MS/MS Assay for Analyzing Multiple Drugs of Abuse in Oral Fluids Using Novel Features in Sample Preparation and Chromatographic Conditions},
journal = {Journal of Mass Spectrometry},
year = {2025},
volume = {60},
number = {5},
doi = {10.1002/jms.5132}
}
EUVIMED