EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Diagnostic accuracy of ultrasonographic optic nerve sheath diameter for detecting increased intracranial pressure in traumatic brain injury: An umbrella review on previous systematic reviews

Amirreza Peyrovinasab, Sepehr Moghaddam, Mahrokh Janmohamadi, Pardis Soroush, Saeed Safari, Mahmoud Yousefifard

Hong Kong Journal of Emergency Medicine · 2026-10 · 33 (5)

DOI: 10.1002/hkj2.70136 ↗
AbstractBibliografische Angaben

Abstract

Abstract Background Traumatic brain injury (TBI) frequently results in increased intracranial pressure (ICP), which may cause irreversible damage or fatality if not addressed. Prompt and precise detection of ICP is essential, particularly in emergency situations. Objectives Ultrasonographic measurement of optic nerve sheath diameter (ONSD) has been suggested as a noninvasive technique for identifying ICP. This study seeks to evaluate the diagnostic accuracy of ONSD through ultrasonography in TBI patients. Methods An umbrella review was performed in accordance with preferred reporting items for systematic reviews and meta‐analyses guidelines, concentrating on systematic reviews and meta‐analyses that detail diagnostic accuracy metrics for ONSD in TBI patients. Studies were incorporated if they provided data on sensitivity, specificity, or area under the curve (AUC) for ONSD in the detection of ICP. The AMSTAR 2 tool was used to figure out the risk of bias, and random‐effects models were used to put the results together. Results The combined analysis of 41 incorporated studies, showed that the test was very accurate: it had a sensitivity of 0.89 (95% CI: 0.85–0.92), a specificity of 0.84 (95% CI: 0.80–0.89), and an AUC of 0.94 (95% CI: 0.91–0.95). The diagnostic odds ratio was 46 (95% CI: 26–81). Subgroup analyses demonstrated consistency among ONSD cut‐off values and ICP thresholds, notwithstanding significant heterogeneity. Conclusions Ultrasonography measurement of ONSD shows that it is very accurate for finding high ICP in TBI patients. It offers a dependable, noninvasive screening instrument, especially in emergency contexts. Nevertheless, standardized measurement protocols and additional research are essential to enhance diagnostic thresholds.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →