EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Core–Shell Molecularly Imprinted Polymer@SiO 2 @Fe 3 O 4 for Low‐Cost and Selective Electrochemical Sensing of Paraquat

M. Ashraful Kader, Gang Li, Yang Liu

ChemElectroChem · 03.11.2026 · 13 (21)

DOI: 10.1002/celc.70332 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ChemElectroChem, online erschienen am 14.10.2026. Verfasst von M. Ashraful Kader und 2 weiteren Autor:innen. Die Arbeit nennt 74 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: James Cook University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The widespread use of the water‐soluble paraquat (PQ) herbicide has found to be linked with numerous toxic outcomes to humans as well as aquatic animals, while the on‐site and rapid measurement is still challenging due to unsuitability and lack of selectivity of the existing techniques. This study presents a selective, sensitive, and low‐cost electrochemical sensor for detecting residual PQ in water by combining a core–shell molecularly imprinted polymer (MIP)@SiO 2 @Fe 3 O 4 material with a portable screen‐printed carbon electrode (SPCE). Adsorptive stripping voltammetry (AdSV) was employed to determine PQ using the proposed MIP@SiO 2 @Fe 3 O 4 /SPCE, exhibiting high analytical performance with a sensitivity of 7.27 µA/µM, a two‐segment linear range of 0.25–20 and 20–50 µM, and a detection limit of 0.043 µM. In addition, excellent selectivity towards PQ was achieved, even in the presence of a 20‐fold excess of interfering substances commonly found in various water matrices. Recoveries of 89.72%–113.46% were obtained at the MIP@SiO 2 @Fe 3 O 4 /SPCE for the determination of PQ in tap water, river water, and seawater samples, and the results were validated using high‐performance liquid chromatography, demonstrating its strong potential for practical applications in aquatic analysis.

Förderung

  • James Cook University

Zitieren

APA

Kader, M. A., Li, G., & Liu, Y. (2026). Core–Shell Molecularly Imprinted Polymer@SiO 2 @Fe 3 O 4 for Low‐Cost and Selective Electrochemical Sensing of Paraquat. ChemElectroChem, 13(21). https://doi.org/10.1002/celc.70332

Vancouver

Kader MA, Li G, Liu Y. Core–Shell Molecularly Imprinted Polymer@SiO 2 @Fe 3 O 4 for Low‐Cost and Selective Electrochemical Sensing of Paraquat. ChemElectroChem. 2026;13(21). doi:10.1002/celc.70332

BibTeX
@article{Kader2026,
  author = {Kader, M. Ashraful and Li, Gang and Liu, Yang},
  title = {Core–Shell Molecularly Imprinted Polymer@SiO 2 @Fe 3 O 4 for Low‐Cost and Selective Electrochemical Sensing of Paraquat},
  journal = {ChemElectroChem},
  year = {2026},
  volume = {13},
  number = {21},
  doi = {10.1002/celc.70332}
}
Kostenlos starten →