EUVIMEDEUVIMED entdecken
Fallbericht

Simultaneous Aortic and Mitral Valve‐in‐Valve Replacement Using Balloon‐Expandable MyVal Valves With Bioprosthetic Valve Fracture

Nitin Bajaj iD, Navreet Singh iD, Ankush Gupta iD, Sunny Pathania iD

Catheterization and Cardiovascular Interventions · 09.11.2026

DOI: 10.1002/ccd.71007 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 09.11.2026. Verfasst von Nitin Bajaj und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Army Institute of Cardiothoracic Sciences, Pune, India. Die Arbeit nennt 8 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Valve‐in‐valve transcatheter aortic valve replacement and mitral valve replacement have proved to be a viable alternative to redo surgery in patients who have bioprosthetic valve dysfunction. There is a large subgroup of patients who undergo double valve replacement with bioprosthetic valves, especially in patients with rheumatic heart disease. Failure of these bioprosthetic valves would require a transcatheter management strategy. Transcatheter double valve replacement (TDVR) in these complex cases would require careful evaluation and planning of valve sizing, aortomitral interactions, access, and residual gradients. A 73‐year‐old man with rheumatic heart disease and prior double bioprosthetic valve replacement in 2014 presented with New York Heart Association class (NYHA) III dyspnea and exertional pre‐syncope. He had severe stenosis of a 19 mm Perimount Magna aortic bioprosthesis and a 27 mm Perimount Magna mitral bioprosthesis, with pulmonary hypertension. Computed tomography demonstrated suitable anatomy for transcatheter valve‐in‐valve treatment. He underwent successful TDVR with a 20 mm MyVal balloon‐expandable in the aortic position, followed by a post‐implantation valve fracture, and a 27.5 mm MyVal transseptally in the mitral position. The final mean gradients were 15 mmHg across the aortic valve and 6 mmHg across the mitral valve at discharge. At 1‐year follow‐up, the patient remained clinically well without an increase in valve gradients. Simultaneous transcatheter aortic and mitral valve‐in‐valve replacement can be performed successfully in selected high‐risk patients after meticulous multimodality planning. In patients with a small surgical aortic bioprosthesis, intentional bioprosthetic valve fracture may be an important adjunct to optimize post‐implantation hemodynamics. This report highlights the complexity of procedural planning for bioprosthetic valve fracture in a small aortic valve, ensuring optimal hemodynamics and the safety and durability of the Myval transcatheter heart valve in challenging and complex procedures like TDVR.

Schlagwörter

Stichwörter der Autor:innen

bioprosthetic valve fracturetranscatheter double valve replacementvalve in valve

Autor:innen und Institutionen

  • Department of Cardiology, Army Institute of Cardiothoracic Sciences, Pune, India.

ORCID-Profile: Nitin Bajaj, Navreet Singh, Ankush Gupta, Sunny Pathania

Zitieren

APA

Bajaj, N., Singh, N., Gupta, A., & Pathania, S. (2026). Simultaneous Aortic and Mitral Valve‐in‐Valve Replacement Using Balloon‐Expandable MyVal Valves With Bioprosthetic Valve Fracture. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.71007

Vancouver

Bajaj N, Singh N, Gupta A, Pathania S. Simultaneous Aortic and Mitral Valve‐in‐Valve Replacement Using Balloon‐Expandable MyVal Valves With Bioprosthetic Valve Fracture. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.71007

BibTeX
@article{Bajaj2026,
  author = {Bajaj, Nitin and Singh, Navreet and Gupta, Ankush and Pathania, Sunny},
  title = {Simultaneous Aortic and Mitral Valve‐in‐Valve Replacement Using Balloon‐Expandable MyVal Valves With Bioprosthetic Valve Fracture},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  doi = {10.1002/ccd.71007}
}