Transcatheter Pulmonary Valve Replacement With a Novel Valve: Medium‐Term Results From a Single Center Study
Catheterization and Cardiovascular Interventions · 2026
DOI: 10.1002/ccd.70405 ↗Kurz gefasst
Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, 2026. Verfasst von Robin H S Chen und 8 weiteren Autor:innen. Beteiligte Einrichtung: Cardiology Unit, Department of Medicine, Queen Mary Hospital, Pok Fu Lam, Hong Kong. Hauptthemen laut MEDLINE: Pulmonary Valve, Pulmonary Valve Insufficiency, Heart Valve Prosthesis Implantation, Cardiac Catheterization. Die Arbeit nennt 21 Literaturangaben.
Abstract (Originalsprache)
Background
Transcatheter pulmonary valve replacement (tPVR) has emerged as a promising management strategy for dysfunctional right ventricular outflow tract (RVOT). However, the management of chronic pulmonary regurgitation (PR) in native or patched RVOT remains challenging with the vast variation in morphology, leading to the demand for novel self‐expandable valves.
Objective
To report procedural performance and medium‐term follow‐up data of the Med Zenith PT‐Valve for tPVR in native or patched RVOT from a single‐center feasibility trial.
Methods
Fifteen patients with PR were recruited for candidacy assessment, with 12 tPVR procedures performed with per‐protocol follow‐up.
Results
Amongst patients recruited, one with concomitant aortic pathology was diverted to surgery; there was one screen failure (7.1%) and one patient withdrew consent. Twelve patients underwent tPVR with the study valve with 100% success rate. Complications included one wire‐related pulmonary hemorrhage, one transient brachial neuropraxia, one femoral pseudoaneurysm, and two patients with non‐sustained ventricular tachycardia Day 1 post‐tPVR. Both patients received a short course of a beta‐blocker without recurrence of arrhythmia. There were no deaths or valve‐related reinterventions with a median follow‐up of 28.5 months (range 17.9–40.0 months). One episode of infective endocarditis was managed conservatively with antibiotics with no sequelae. There were otherwise no late complications. Significant improvement in biventricular volume and PR fraction was observed.
Conclusion
The Med Zenith PT‐Valve has performed well over short to mid‐term follow‐up in patients with significant PR in native or patched RVOT. Future studies are required to elucidate the longevity of the valve.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiology Unit, Department of Medicine, Queen Mary Hospital, Pok Fu Lam, Hong Kong.
- Cardiology Centre, Department of Paediatrics and Adolescent Medicine, Hong Kong Children's Hospital, Kowloon City, Hong Kong.
- Department of Paediatrics, Chinese University of Hong Kong Medical Centre, Kowloon City, Hong Kong.
- Pediatrics and Internal Medicine, Cardiology, The Ohio State University, Columbus, Ohio, USA.
ORCID-Profile: Robin H S Chen, Alston Conrad Chiu, Pak-Cheong Chow, Adolphus K T Chau
Zitieren
APA
Chen, R. H. S., Un, T. K. C., Yu, C. K. M., Chiu, A. C., Chow, P. C., Lun, K. S., Lam, S., Chau, A. K. T., & Cheatham, J. P. (2026). Transcatheter Pulmonary Valve Replacement With a Novel Valve: Medium‐Term Results From a Single Center Study. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70405
Vancouver
Chen RHS, Un TKC, Yu CKM, Chiu AC, Chow PC, Lun KS, et al. Transcatheter Pulmonary Valve Replacement With a Novel Valve: Medium‐Term Results From a Single Center Study. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70405
BibTeX
@article{Chen2026,
author = {Chen, Robin H S and Un, Timothy K C and Yu, Clement K M and Chiu, Alston Conrad and Chow, Pak-Cheong and Lun, Kin-Shing and Lam, Simon and Chau, Adolphus K T and Cheatham, John P},
title = {Transcatheter Pulmonary Valve Replacement With a Novel Valve: Medium‐Term Results From a Single Center Study},
journal = {Catheterization and Cardiovascular Interventions},
year = {2026},
doi = {10.1002/ccd.70405}
}
EUVIMED