Transcatheter Aortic Valve‐in‐Valve Implantation for Failing Stentless Bioprosthetic Aortic Valves: An International Multicentre Retrospective Analysis
Catheterization and Cardiovascular Interventions · 2026
DOI: 10.1002/ccd.70376 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2026. Verfasst von Clare Rayner und 18 weiteren Autor:innen. Beteiligte Einrichtung: Royal Hobart Hospital, Hobart, Tasmania, Australia. Hauptthemen laut MEDLINE: Bioprosthesis, Heart Valve Prosthesis, Prosthesis Failure, Transcatheter Aortic Valve Replacement. Die Arbeit nennt 27 Literaturangaben.
Abstract (Originalsprache)
Background
Valve‐in‐valve aortic valve implantation (ViV‐TAVI) offers a less invasive treatment option for patients with a failing surgical bioprosthesis, avoiding the need for redo surgery. ViV‐TAVI within a stentless bioprosthetic valve poses unique technical challenges. We report an international, multicentre experience evaluating procedural and clinical outcomes for patients undergoing ViV‐TAVI for failed stentless bioprosthetic aortic valves.
Aims
To evaluate the procedural feasibility, safety, and clinical outcomes of ViV‐TAVI performed for failed stentless bioprosthetic aortic valves in an international, multicentre cohort.
Methods
We retrospectively analysed 65 patients who underwent ViV‐TAVI for stentless valve failure between 2010 and 2024. Outcome endpoints were based on the Valve Academic Research Consortium 3 (VARC‐3) criteria.
Results
Sixty‐five patients (mean age 78.8 ± 10.2 years; 66.1% male; mean STS‐PROM 6.9 ± 4.7) were included. The mean interval between surgical valve implantation and failure was 12.9 ± 4.1 years, with regurgitation the predominant mechanism of valve dysfunction (52.3%). Procedural success was achieved in 92.3%. 17 patients (26.2%) had upfront coronary protection. Despite this, six patients required unplanned percutaneous coronary intervention (PCI) for coronary obstruction. The 30‐day and 1‐year mortality rate was 0% and 8% respectively.
Conclusions
ViV‐TAVI was an effective intervention for patients with failing stentless bioprosthetic valves, with high procedural success rates despite unique technical challenges. Careful preprocedural imaging, planning, and implementation of coronary protection strategies are critical for optimal patient outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Royal Hobart Hospital, Hobart, Tasmania, Australia.
- Victorian Heart Hospital, Clayton, Victoria, Australia.
- St Thomas Hospital, London, UK.
- Department of Cardiology, Inselspital, Bern University Hospital, Bern, Switzerland.
- Rabin Medical Center, Petah Tikva, Israel.
- Humanitas Research Hospital Milan, Rozzano, Milan, Italy.
ORCID-Profile: Clare Rayner, Daijiro Tomii, Ran Kornowski, Antonio Mangieri, Francesco Tartaglia, Ole De Backer, Mariama Akodad
Zitieren
APA
Rayner, C., Paleri, S., Satpal, A., Tomii, D., Pilgrim, T., Codner, P., Kornowski, R., Mangieri, A., Tartaglia, F., Mauri, V., De Backer, O., Kobari, Y., Nombela-Franco, L., Ielasi, A., Akodad, M., Sava, R., Patterson, T., Redwood, S., & Adams, H. (2026). Transcatheter Aortic Valve‐in‐Valve Implantation for Failing Stentless Bioprosthetic Aortic Valves: An International Multicentre Retrospective Analysis. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70376
Vancouver
Rayner C, Paleri S, Satpal A, Tomii D, Pilgrim T, Codner P, et al. Transcatheter Aortic Valve‐in‐Valve Implantation for Failing Stentless Bioprosthetic Aortic Valves: An International Multicentre Retrospective Analysis. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70376
BibTeX
@article{Rayner2026,
author = {Rayner, Clare and Paleri, Sarang and Satpal, Arri and Tomii, Daijiro and Pilgrim, Thomas and Codner, Pablo and Kornowski, Ran and Mangieri, Antonio and Tartaglia, Francesco and Mauri, Victor and De Backer, Ole and Kobari, Yusuke and Nombela-Franco, Luis and Ielasi, Alfonso and Akodad, Mariama and Sava, Ruxandra and Patterson, Tiffany and Redwood, Simon and Adams, Heath},
title = {Transcatheter Aortic Valve‐in‐Valve Implantation for Failing Stentless Bioprosthetic Aortic Valves: An International Multicentre Retrospective Analysis},
journal = {Catheterization and Cardiovascular Interventions},
year = {2026},
doi = {10.1002/ccd.70376}
}
EUVIMED