EUVIMEDEUVIMED entdecken
Vergleichsstudie

Are Ultrathin Stents Optimal for Bifurcation Lesions? Insights From Computational Modeling of Provisional and DK‐Crush Techniques

Andrea Colombo iD, Dario Carbonaro, Mingzi Zhang, Chi Shen, Ramtin Gharleghi, Ankush Kapoor, Claudio Chiastra, Nigel Jepson, Mark Webster iD, Susann Beier

Catheterization and Cardiovascular Interventions · 2026

DOI: 10.1002/ccd.70329 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2026. Verfasst von Andrea Colombo und 9 weiteren Autor:innen. Beteiligte Einrichtung: Sydney Vascular Modelling Group, School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, New South Wales, Australi…. Hauptthemen laut MEDLINE: Models, Cardiovascular, Stents, Coronary Artery Disease, Computer Simulation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 59 Literaturangaben. Gefördert von: The authors received no specific funding for this work..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Complex coronary bifurcation lesions remain challenging in percutaneous coronary intervention, with stent design and deployment strategy influencing clinical outcomes.

Aims

This study compares the mechanical and hemodynamic performance of the ultrathin‐strut Orsiro and thin‐strut Xience Sierra stent in provisional side branch (PSB) and double kissing crush (DKC) techniques.

Methods

We used finite element analyses of bifurcation stent deployment to assess malapposition, ostium clearance, and arterial wall stress for both techniques. Computational fluid dynamics simulations quantified the luminal exposure to low time‐averaged endothelial shear stress (TAESS < 0.4 Pa) and high shear rates (> 1000 s⁻¹).

Results

In PSB, Orsiro showed higher malapposition (13.0% vs. 9.6%) but improved SB ostium clearance (77% vs. 64%) and lower low‐TAESS exposure (30.3% vs. 33.6%) compared to Xience. Orsiro also produced higher arterial wall stresses, particularly during kissing balloon inflation. In DKC, differences in malapposition and ostium clearance diminished between stents, though Orsiro retained a hemodynamic advantage with lower low‐TAESS (28.2% vs. 36.3%).

Conclusions

Stent design influenced outcomes more strongly in PSB, where anatomical interaction and platform‐specific behavior impacted both structural and hemodynamic results. In DKC, procedural complexity minimized those differences, making the stenting technique the primary performance driver. Nonetheless, Orsiro consistently preserved more favorable flow conditions. These findings highlight the need to match device selection with lesion characteristics in PSB, while in DKC, optimizing procedural steps may have a greater impact than the choice of stent platform.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Models, CardiovascularStentsCoronary Artery DiseaseComputer SimulationCoronary VesselsPercutaneous Coronary InterventionAngioplasty, Balloon, CoronaryPatient-Specific ModelingHumansProsthesis DesignFinite Element AnalysisStress, MechanicalHemodynamicsTreatment OutcomeCoronary AngiographyCoronary Circulation

Stichwörter der Autor:innen

computational fluid dynamicscoronary bifurcation stentingdouble kissing crushfinite element analysisprovisional side branchstent

Autor:innen und Institutionen

  • Sydney Vascular Modelling Group, School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, New South Wales, Australia.
  • PolitoBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.
  • Centre for Healthy Futures, Torrens University Australia, Surry Hills, Sydney, Australia.
  • Independent Researcher.
  • Prince of Wales Clinical School of Medicine, University of New South Wales, Sydney, New South Wales, Australia.
  • Prince of Wales Hospital, Sydney, New South Wales, Australia.

ORCID-Profile: Andrea Colombo, Mark Webster

Förderung

  • The authors received no specific funding for this work.

Zitieren

APA

Colombo, A., Carbonaro, D., Zhang, M., Shen, C., Gharleghi, R., Kapoor, A., Chiastra, C., Jepson, N., Webster, M., & Beier, S. (2026). Are Ultrathin Stents Optimal for Bifurcation Lesions? Insights From Computational Modeling of Provisional and DK‐Crush Techniques. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70329

Vancouver

Colombo A, Carbonaro D, Zhang M, Shen C, Gharleghi R, Kapoor A, et al. Are Ultrathin Stents Optimal for Bifurcation Lesions? Insights From Computational Modeling of Provisional and DK‐Crush Techniques. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70329

BibTeX
@article{Colombo2026,
  author = {Colombo, Andrea and Carbonaro, Dario and Zhang, Mingzi and Shen, Chi and Gharleghi, Ramtin and Kapoor, Ankush and Chiastra, Claudio and Jepson, Nigel and Webster, Mark and Beier, Susann},
  title = {Are Ultrathin Stents Optimal for Bifurcation Lesions? Insights From Computational Modeling of Provisional and DK‐Crush Techniques},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  doi = {10.1002/ccd.70329}
}
Kostenlos starten →