Utility of Long Radial Artery Sheaths for Left Heart Catheterization
Catheterization and Cardiovascular Interventions · 2025
DOI: 10.1002/ccd.70267 ↗Kurz gefasst
Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Aarash Roshandel und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, NYU Langone Health, New York, USA. Hauptthemen laut MEDLINE: Radial Artery, Cardiac Catheterization, Catheterization, Peripheral, Cardiac Catheters. Die Arbeit nennt 12 Literaturangaben. Gefördert von: The authors received no specific funding for this work..
Abstract (Originalsprache)
Background
Increased vessel tortuosity may hinder the success of transradial procedures. Longer thin‐walled, hydrophilic sheaths ≥ 75 cm can be placed into the ascending aorta and have the potential to avoid femoral access crossover.
Methods
We studied consecutive cases of patients undergoing left heart catheterization (LHC) where a 75 cm long thin‐walled, hydrophilic sheath was used from 1/1/22 to 9/30/24. Patient and procedural characteristics were collected. Procedural data included indication, contrast load, radiation dose, procedural time, procedural complications, and the need to convert to femoral access.
Results
Our study sample included 71 patients (mean age 69, 45% male). Comorbidities included hypertension (82%), hyperlipidemia (76%), and congestive heart failure (30%). Previous coronary artery disease was present in 31% of patients, and 20% of patients had undergone previous percutaneous coronary intervention (PCI). Indications for LHC included symptoms of stable ischemic heart disease (21%), abnormal non‐invasive ischemic testing (52%), acute coronary syndrome (18%), and pre‐operative evaluation for surgery (8%). The reason to switch to the long thin‐walled, hydrophilic sheath was inability to engage the coronaries due to subclavian/brachiocephalic artery tortuosity (86%) or radial artery spasm (14%). After switching to the long thin‐walled, hydrophilic sheath, 62/71 (87%) cases successfully engaged the coronaries without converting to femoral access. The mean procedure time was 36 min for diagnostic LHC cases ( n = 46) and 72 min for PCI cases ( n = 25). No procedural complications occurred.
Conclusion
This case series suggests that use of the long thin‐walled, hydrophilic radial sheaths can avoid femoral access crossover in selected cases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Internal Medicine, NYU Langone Health, New York, USA.
- Leon H. Charney Division of Cardiology, NYU Langone Health, New York, USA.
ORCID-Profile: Aarash Roshandel
Förderung
- The authors received no specific funding for this work.
Zitieren
APA
Roshandel, A., Shields, D., Abaza, E., Razzouk, L., Rao, S. V., & Junarta, J. (2025). Utility of Long Radial Artery Sheaths for Left Heart Catheterization. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70267
Vancouver
Roshandel A, Shields D, Abaza E, Razzouk L, Rao SV, Junarta J. Utility of Long Radial Artery Sheaths for Left Heart Catheterization. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.70267
BibTeX
@article{Roshandel2025,
author = {Roshandel, Aarash and Shields, Danielle and Abaza, Ehab and Razzouk, Louai and Rao, Sunil V and Junarta, Joey},
title = {Utility of Long Radial Artery Sheaths for Left Heart Catheterization},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
doi = {10.1002/ccd.70267}
}