EUVIMEDEUVIMED entdecken
VergleichsstudieKohortenstudieOpen Access · CC BY-NC-ND 4.0

Comparison of in‐Hospital Complication Rates After Transcatheter Aortic Valve Replacement in Patients With Bicuspid Versus Tricuspid Aortic Valves: A Retrospective Cohort Study

Tingxi Zhu, Jiawei Luo iD, Xuan Huang, Lulu Liu, Kehan Li, Wei He, Xiaobo Zhou, Yingqiang Guo, Xiaoyan Yang

Catheterization and Cardiovascular Interventions · 2025

DOI: 10.1002/ccd.70206 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Tingxi Zhu und 8 weiteren Autor:innen. Beteiligte Einrichtung: West China Biomedical Big Data Center, West China Hospital/West China School of Medicine, Sichuan University, Chengdu, Sichuan, China. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Aortic Valve, Heart Valve Diseases, Postoperative Complications. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: This work was supported by the projects of the Department of Science and Technology of Sichuan Province (grant number 2023YFS0200 to Xiaobo Zhou) and the 1⋅3⋅5….

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Transcatheter aortic valve replacement (TAVR) has become a popular alternative to surgical aortic valve replacement (SAVR) for patients with valvular heart disease (VHD), particularly for those with aortic anomalies.

Aims

The study aimed to compare the risks of post‐TAVR complications between patients with bicuspid and tricuspid aortic valves and to identify associated risk factors.

Methods

The association between complications and valve type (bicuspid or tricuspid) was assessed. The study also explored various combinations of factors to understand their impact on complications. Separate analyses were conducted to identify specific risk factors for each complication.

Results

Out of the 1154 eligible patients, 508 had bicuspid aortic valves (BAV) and 646 had tricuspid aortic valves (TAV). The study identified 40 cases of acute kidney injury, 134 instances of new‐onset permanent pacemaker implantations, 129 occurrences of paravalvular leak, and 30 device successes. The comprehensive logistic regression revealed no statistically significant association between complications and valve type (ORs: 0.52 (95% CI, 0.23−1.09) for acute kidney injury, 1.29 (95% CI, 0.87−1.92) for permanent pacemaker implantation, 1.29 (95% CI, 0.82−2.02) for paravalvular leak, and 0.54 (95% CI, 0.22−1.23) for device success). Total bilirubin (TBIL), albumin (ALB), age, and New York Heart Association (NYHA) scores, among other factors, were associated with specific post‐TAVR complications.

Conclusions

The incidence of acute kidney injury, new permanent pacemaker implantations, paravalvular leaks, and device success did not differ significantly between patients with BAV and TAV following TAVR. Specific risk factors for these complications were identified, highlighting the importance of careful clinical monitoring in post‐TAVR management.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Transcatheter Aortic Valve ReplacementAortic ValveHeart Valve DiseasesPostoperative ComplicationsAortic Valve StenosisHumansMaleRetrospective StudiesFemaleRisk FactorsBicuspid Aortic Valve DiseaseTreatment OutcomeAgedAged, 80 and overRisk AssessmentTime FactorsAcute Kidney InjuryPacemaker, ArtificialHeart Valve ProsthesisCardiac Pacing, Artificial

Stichwörter der Autor:innen

bicuspid aortic valves (BAV)cohort studycomplicationstranscatheter aortic valve replacement (TAVR)tricuspid aortic valves (TAV)

Autor:innen und Institutionen

  • West China Biomedical Big Data Center, West China Hospital/West China School of Medicine, Sichuan University, Chengdu, Sichuan, China.
  • Department of Cardiovascular Surgery, West China Hospital/West China School of Medicine, Sichuan University, Chengdu, Sichuan, China.
  • Department of Health Behavior and Social Medicine, West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu, China.
  • Center for Computational Systems Medicine, McWilliams School of Biomedical Informatics, The University of Texas Health Science Center at Houston, Houston, Texas, USA.

ORCID-Profile: Jiawei Luo

Förderung

  • This work was supported by the projects of the Department of Science and Technology of Sichuan Province (grant number 2023YFS0200 to Xiaobo Zhou) and the 1⋅3⋅5…

Zitieren

APA

Zhu, T., Luo, J., Huang, X., Liu, L., Li, K., He, W., Zhou, X., Guo, Y., & Yang, X. (2025). Comparison of in‐Hospital Complication Rates After Transcatheter Aortic Valve Replacement in Patients With Bicuspid Versus Tricuspid Aortic Valves: A Retrospective Cohort Study. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70206

Vancouver

Zhu T, Luo J, Huang X, Liu L, Li K, He W, et al. Comparison of in‐Hospital Complication Rates After Transcatheter Aortic Valve Replacement in Patients With Bicuspid Versus Tricuspid Aortic Valves: A Retrospective Cohort Study. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.70206

BibTeX
@article{Zhu2025,
  author = {Zhu, Tingxi and Luo, Jiawei and Huang, Xuan and Liu, Lulu and Li, Kehan and He, Wei and Zhou, Xiaobo and Guo, Yingqiang and Yang, Xiaoyan},
  title = {Comparison of in‐Hospital Complication Rates After Transcatheter Aortic Valve Replacement in Patients With Bicuspid Versus Tricuspid Aortic Valves: A Retrospective Cohort Study},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2025},
  doi = {10.1002/ccd.70206}
}
Kostenlos starten →