EUVIMEDEUVIMED entdecken
Vergleichsstudie

Minimal Microvascular Resistance: Agreement Between Continuous and Bolus Thermodilution

Thabo Mahendiran iD, Daniëlle Keulards, Nico H J Pijls, Michele Viscusi, Emanuele Gallinoro iD, Dario Bertolone, Peter Damman, Niels van Royen, Jeroen Sonck, Carlos Collet, Adriaan Wilgenhof, Paul Knaapen iD und 1 weitere

Catheterization and Cardiovascular Interventions · 2025

DOI: 10.1002/ccd.31515 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Thabo Mahendiran und 12 weiteren Autor:innen. Beteiligte Einrichtung: Cardiovascular Center Aalst, OLV Clinic, Aalst, Belgium. Hauptthemen laut MEDLINE: Vascular Resistance, Microcirculation, Coronary Circulation, Coronary Vessels. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: The authors received no specific funding for this work..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Continuous thermodilution quantifies absolute microvascular resistance (R μ , Wood units), a key metric of microvascular function. R μ is minimal during hyperemia (R μ,hyper ) with increased R μ,hyper suggestive of microvascular dysfunction. Bolus thermodilution measures the index of microcirculatory resistance (IMR), a dimensionless surrogate of R μ,hyper .

Aims

We compared R μ,hyper measured by continuous thermodilution (invasive R μ,hyper ) with the gold standard [ 15 O]H 2 O positron emission tomography (PET R μ,hyper ), and assessed the correlation between invasive R μ ,hyper and IMR.

Methods

First, the accuracy of invasive R μ,hyper was assessed in a cohort of 24 patients in which both invasive R μ,hyper and PET R μ,hyper were measured in the left anterior descending (LAD) and circumflex (LCX) arteries, corresponding to 46 measurements of R μ,hyper in total (LAD = 24, LCX = 22). Next, agreement between invasive R μ,hyper and IMR was evaluated in the LAD in a cohort of 250 patients with angina and non‐obstructive coronary arteries.

Results

Invasive R μ,hyper exhibited a strong correlation with PET R μ,hyper (r = 0.86 [95% CI 0.76–0.92], p < 0.001), with good absolute agreement (ICC 0.82 [95% CI 0.70–0.90], p < 0.001). Passing‐Bablok regression analysis found no significant systematic (intercept A: 54.53 [95% CI ‐18.95 to 120.96]) or proportional (slope B: 0.90 [95% CI 0.71–1.15]) bias between invasive R μ,hyper and PET R μ,hyper . However, invasive R μ,hyper exhibited no significant correlation with IMR (r = 0.11 [95% CI ‐0.01 to 0.23], p = 0.08).

Conclusion

Invasive R μ,hyper derived from continuous thermodilution exhibited excellent agreement with noninvasive R μ,hyper measured by [ 15 O]H 2 O PET, the current non‐invasive standard of reference. In contrast, IMR exhibited no significant correlation with invasive R μ,hyper in patients with angina and non‐obstructive coronary arteries.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Vascular ResistanceMicrocirculationCoronary CirculationCoronary VesselsPositron-Emission TomographyAngina PectorisCardiac CatheterizationCoronary Artery DiseaseHumansThermodilutionMaleFemaleMiddle AgedPredictive Value of TestsAgedReproducibility of ResultsHyperemiaRadiopharmaceuticals

Stichwörter der Autor:innen

angina and nonobstructive coronary arteriesbolus thermodilutioncontinuous thermodilutioncoronary microvascular dysfunctionminimal microvascular resistance

Substanzen

Radiopharmaceuticals

Autor:innen und Institutionen

  • Cardiovascular Center Aalst, OLV Clinic, Aalst, Belgium.
  • Department of Cardiology, Lausanne University Hospital, Lausanne, Switzerland.
  • Department of Cardiology, Catharina Hospital, Eindhoven, The Netherlands.
  • Department of University Cardiology, IRCC Galeazzi Sant'Ambrogio Hospital, Milan, Italy.
  • Department of Cardiology, Radboud Hospital, Nijmegen, The Netherlands.
  • Department of Clinical and Molecular Medicine, Sapienza University, Rome, Italy.

ORCID-Profile: Thabo Mahendiran, Emanuele Gallinoro, Paul Knaapen

Förderung

  • The authors received no specific funding for this work.

Zitieren

APA

Mahendiran, T., Keulards, D., Pijls, N. H. J., Viscusi, M., Gallinoro, E., Bertolone, D., Damman, P., van Royen, N., Sonck, J., Collet, C., Wilgenhof, A., Knaapen, P., & De Bruyne, B. (2025). Minimal Microvascular Resistance: Agreement Between Continuous and Bolus Thermodilution. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31515

Vancouver

Mahendiran T, Keulards D, Pijls NHJ, Viscusi M, Gallinoro E, Bertolone D, et al. Minimal Microvascular Resistance: Agreement Between Continuous and Bolus Thermodilution. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31515

BibTeX
@article{Mahendiran2025,
  author = {Mahendiran, Thabo and Keulards, Daniëlle and Pijls, Nico H J and Viscusi, Michele and Gallinoro, Emanuele and Bertolone, Dario and Damman, Peter and van Royen, Niels and Sonck, Jeroen and Collet, Carlos and Wilgenhof, Adriaan and Knaapen, Paul and De Bruyne, Bernard},
  title = {Minimal Microvascular Resistance: Agreement Between Continuous and Bolus Thermodilution},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2025},
  doi = {10.1002/ccd.31515}
}
Kostenlos starten →