Validierungsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 26.03.2025. Verfasst von Xinzhou Xie und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Information Engineering, School of Electronics and Information, Northwestern Polytechnical University, Xi'an, Shaanxi, P.R. China. Hauptthemen laut MEDLINE: Fractional Flow Reserve, Myocardial, Coronary Angiography, Myocardial Perfusion Imaging, Coronary Vessels. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: This work was supported by the General Project of Shaanxi Province Key Research and Development Plan (2024GX-YBXM-136), the Clinical Research Project of Air Fo….

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

With a 3D model reconstructed from coronary angiography, intracoronary blood flow can be calculated using a computational fluid dynamics (CFD) model with fractional flow reserve (FFR) measured pressure as boundary conditions.

Aims

The aim of this study is to investigate the clinical feasibility of this method by evaluating its ability to identify myocardial ischemia diagnosed by SPECT myocardial perfusion imaging (MPI).

Methods

Patients who underwent both SPECT‐MPI and coronary angiography with FFR within 1 week were enrolled. Based on the summed stress score (SSS) and summed difference score (SDS) of SPECT MPI, myocardial ischemia in individual coronary territories was identified. Mean flow rate ( Q ), total flow resistance (TFR), absolute microvascular resistance (AMR) and their corresponding resting state indices were computed using the novel CFD model.

Results

A total of 52 patients with 53 vessels were investigated. Based on SPECT MPI, 23 patients (43.4%) were associated with abnormal MPI. Q was significant higher in normal MPI group compared with abnormal MPI group (59.68 ± 40.33 mL/min vs. 25.67 ± 21.55 mL/min, p < 0.001). The TFR were significantly lower in normal MPI group (TFR: 1898.25 ± 951.55 mmHg min/L vs. 4786.31 ± 3056.18 mmHg min/L, p < 0.001). The ROC‐AUC of Q and TFR for discriminating normal and abnormal MPI were 0.876 (95% CI: 0.783–0.970, p < 0.001) and 0.854 (95% CI: 0.745–0.963, p < 0.001).

Conclusions

Intracoronary flow assessed by the novel CFD based method has shown promise in accurately identifying patients with abnormal SPECT MPI, offering a convenient and quantitative approach for assessing coronary physiology.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fractional Flow Reserve, MyocardialCoronary AngiographyMyocardial Perfusion ImagingCoronary VesselsTomography, Emission-Computed, Single-PhotonModels, CardiovascularCoronary Artery DiseaseRadiographic Image Interpretation, Computer-AssistedHumansMaleFemaleMiddle AgedPredictive Value of TestsFeasibility StudiesAgedReproducibility of ResultsHydrodynamicsBlood Flow VelocityROC Curve

Stichwörter der Autor:innen

CFDfractional flow reserveintracoronary flowmyocardial ischemia

Autor:innen und Institutionen

  • Department of Information Engineering, School of Electronics and Information, Northwestern Polytechnical University, Xi'an, Shaanxi, P.R. China.
  • Department of Cardiology, Xi'an International Medical Center Hospital, Northwest University, Xi'an, Shaanxi, China.
  • Department of Cardiology, The First Affiliated Hospital of the Fourth Military Medical University, Xi'an, Shaanxi, P.R. China.
  • Department of Nuclear Medicine, The First Affiliated Hospital of the Fourth Military Medical University, Xi'an, Shaanxi, P.R. China.
  • Department of Cardiology, No.971 Hospital of the PLA Navy, Qingdao, Shandong, P.R. China.

ORCID-Profile: Kun Lian

Förderung

  • This work was supported by the General Project of Shaanxi Province Key Research and Development Plan (2024GX-YBXM-136), the Clinical Research Project of Air Fo…

Zitieren

APA

Xie, X., Li, N., Yu, T., Pu, W., Lin, H., Li, X., Li, G., Li, C., Chen, Y., & Lian, K. (2025). Validation of a Novel Computational Fluid Dynamics Based Method for Assessing Intracoronary Flow: Combining Coronary Angiography and Fractional Flow Reserve. Catheterization and Cardiovascular Interventions, 105(7), 1695-1706. https://doi.org/10.1002/ccd.31498

Vancouver

Xie X, Li N, Yu T, Pu W, Lin H, Li X, et al. Validation of a Novel Computational Fluid Dynamics Based Method for Assessing Intracoronary Flow: Combining Coronary Angiography and Fractional Flow Reserve. Catheterization and Cardiovascular Interventions. 2025;105(7):1695-1706. doi:10.1002/ccd.31498

BibTeX
@article{Xie2025,
  author = {Xie, Xinzhou and Li, Na and Yu, Tiantong and Pu, Wenjun and Lin, Heqiang and Li, Xiang and Li, Guoquan and Li, Chengxiang and Chen, Yan and Lian, Kun},
  title = {Validation of a Novel Computational Fluid Dynamics Based Method for Assessing Intracoronary Flow: Combining Coronary Angiography and Fractional Flow Reserve},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2025},
  volume = {105},
  number = {7},
  pages = {1695--1706},
  doi = {10.1002/ccd.31498}
}
Kostenlos starten →