EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC-ND 4.0

Long‐Term Bioprosthetic Valve Durability After Transcatheter Aortic Valve Replacement With Supra‐Annular Self‐Expanding Versus Intra‐Annular Balloon‐Expandable Valves in Patients With a Small Aortic Annulus

Yutaka Matsuhiro iD, Isamu Mizote, Daisuke Nakamura, Tomoharu Dohi iD, Koichi Maeda, Kazuo Shimamura, Ai Kawamura iD, Kizuku Yamashita, Shumpei Kosugi iD, Shota Okuno iD, Hiroki Sugae, Yasuharu Takeda und 1 weitere

Catheterization and Cardiovascular Interventions · 2025

DOI: 10.1002/ccd.31415 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Yutaka Matsuhiro und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Osaka University Graduate School of Medicine, Osaka, Japan. Hauptthemen laut MEDLINE: Heart Valve Prosthesis, Bioprosthesis, Aortic Valve, Aortic Valve Stenosis. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: The authors received no specific funding for this work..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The long‐term valve durability of supra‐annular self‐expanding valves (SEV) and intra‐annular balloon‐expandable valves (BEV) in patients with small aortic annuli remains unexplored.

Aims

This study aimed to determine the long‐term bioprosthetic valve durability with SEV versus BEV in patients with small aortic annuli.

Methods

This retrospective study included patients with severe aortic stenosis (AS) and an aortic annulus area of 430 mm 2 or less who underwent transcatheter aortic valve replacement using SEV and BEV between October 2009 and December 2022. Based on the Valve Academic Research Consortium's three definitions, the endpoints were hemodynamic structural valve deterioration (SVD) and bioprosthetic valve failure (BVF). Inverse probability of treatment weighting (IPTW) was used to compare between the two groups and adjust for baseline characteristics. The Fine‐Gray subdistribution hazard model accounted for the competing risk of death.

Results

In total, 565 patients (204 treated with SEV and 361 treated with BEV) were included. The median follow‐up duration was 3.6 years [2.0 years, 5.7 years], and the maximum was 12.3 years. Hemodynamic SVD and BVF were less frequently identified in the SEV group than in the BEV group (1.1% vs. 9.1% within 5 years, 0.7% vs. 8.1% within 5 years, respectively). On the IPTW adjusted Fine‐Gray subdistribution hazard model analysis, hemodynamic SVD was less frequent in SEV compared with BEV (Hazard Ratio [HR]: 0.16; 95% Confidence Interval [CI]: 0.04–0.56, p = 0.004). SEV was also associated with a lower BVF risk than BEV (HR: 0.25; 95% CI: 0.08–0.76, p = 0.015).

Conclusions

SEV appears to be more suitable for long‐term valve durability in patients with a small aortic annulus.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Valve ProsthesisBioprosthesisAortic ValveAortic Valve StenosisTranscatheter Aortic Valve ReplacementBalloon ValvuloplastyProsthesis FailureHumansRetrospective StudiesMaleFemaleProsthesis DesignTime FactorsTreatment OutcomeAgedAged, 80 and overRisk FactorsHemodynamicsRisk AssessmentSeverity of Illness Index

Stichwörter der Autor:innen

bioprosthetic valve failuresmall aortic annulusstructural valve deteriorationtranscatheter aortic valve replacement

Autor:innen und Institutionen

  • Department of Cardiovascular Medicine, Osaka University Graduate School of Medicine, Osaka, Japan.
  • Department of Cardiovascular Surgery, Osaka University Graduate School of Medicine, Osaka, Japan.

ORCID-Profile: Yutaka Matsuhiro, Tomoharu Dohi, Ai Kawamura, Shumpei Kosugi, Shota Okuno

Förderung

  • The authors received no specific funding for this work.

Zitieren

APA

Matsuhiro, Y., Mizote, I., Nakamura, D., Dohi, T., Maeda, K., Shimamura, K., Kawamura, A., Yamashita, K., Kosugi, S., Okuno, S., Sugae, H., Takeda, Y., & Sakata, Y. (2025). Long‐Term Bioprosthetic Valve Durability After Transcatheter Aortic Valve Replacement With Supra‐Annular Self‐Expanding Versus Intra‐Annular Balloon‐Expandable Valves in Patients With a Small Aortic Annulus. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31415

Vancouver

Matsuhiro Y, Mizote I, Nakamura D, Dohi T, Maeda K, Shimamura K, et al. Long‐Term Bioprosthetic Valve Durability After Transcatheter Aortic Valve Replacement With Supra‐Annular Self‐Expanding Versus Intra‐Annular Balloon‐Expandable Valves in Patients With a Small Aortic Annulus. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31415

BibTeX
@article{Matsuhiro2025,
  author = {Matsuhiro, Yutaka and Mizote, Isamu and Nakamura, Daisuke and Dohi, Tomoharu and Maeda, Koichi and Shimamura, Kazuo and Kawamura, Ai and Yamashita, Kizuku and Kosugi, Shumpei and Okuno, Shota and Sugae, Hiroki and Takeda, Yasuharu and Sakata, Yasushi},
  title = {Long‐Term Bioprosthetic Valve Durability After Transcatheter Aortic Valve Replacement With Supra‐Annular Self‐Expanding Versus Intra‐Annular Balloon‐Expandable Valves in Patients With a Small Aortic Annulus},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2025},
  doi = {10.1002/ccd.31415}
}
Kostenlos starten →