EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieVergleichsstudieOpen Access · CC BY 4.0

Evaluation of microcirculatory protection in percutaneous revascularisation: A stent implantation technique and device comparison

Muhammad Aetesam-Ur-Rahman iD, Tian X Zhao, Kitty Paques, Joana Oliveira iD, Yi-Da Chiu, Melissa Duckworth, Bharat Khialani iD, Stephen Kyranis, Martin R Bennett, Nick E J West, Stephen P Hoole iD

Catheterization and Cardiovascular Interventions · 2024

DOI: 10.1002/ccd.31155 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2024. Verfasst von Muhammad Aetesam-Ur-Rahman und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Interventional Cardiology, Royal Papworth Hospital, Cambridge, UK. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Microcirculation, Drug-Eluting Stents, Prosthesis Design. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Abbott Vascular, Cambridge Biomedical Research Centre, Heart and Lung Research Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Coronary microvascular dysfunction (CMD) after percutaneous coronary intervention (PCI) is prognostically important and may also be a cause of persistent angina. The stent balloon inflation technique or material properties may influence the degree of CMD post‐PCI.

Methods

Thirty‐six patients with stable angina attending for elective PCI were randomized to either slow drug eluting stent (DES) implantation technique (DES slow group): +2 atm. every 5 s., maintained for a further 30 s or a standard stent implantation technique (DES std group): rapid inflation and deflation. PressureWire X with thermodilution at rest and hyperemia and optical coherence tomography (OCT) were performed pre‐ and post‐PCI. Combined primary endpoints were changes in index of microvascular resistance (delta IMR) and coronary flow reserve (delta CFR) following PCI. The secondary endpoints included differences in cardiac troponin I (delta cTnI) at 6 h post‐PCI, Seattle angina questionnaire (SAQ) at 1, 3, 6, and 12 months and OCT measures of stent results immediately post‐PCI and at 3 months.

Results

Both groups were well matched, with similar baseline characteristics and OCT‐defined plaque characteristics. Delta IMR was significantly better in the DES slow PCI arm with a median difference of −4.14 (95% CI ‐10.49, −0.39, p = 0.04 ). Delta CFR was also numerically higher with a median difference of 0.47 (95% CI −0.52, 1.31, p = 0.46). This did not translate to improved delta median cTnI (1.5 (34.8) vs. 0 (27.5) ng/L, p = 0.75) or median SAQ score at 3 months, (85 (20) vs. 95 (17.5), p = 0.47).

Conclusion

Slow stent implantation is associated with less CMD after elective PCI in patients with stable angina.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, Optical CoherenceMicrocirculationDrug-Eluting StentsProsthesis DesignCoronary CirculationHumansMaleFemaleMiddle AgedAgedTreatment OutcomeTime FactorsPercutaneous Coronary InterventionCoronary Artery DiseaseCoronary VesselsProspective StudiesThermodilutionAngina, StableSurveys and QuestionnairesVascular ResistanceCoronary AngiographyAngioplasty, Balloon, Coronary

Stichwörter der Autor:innen

coronary microvascular dysfunctioncoronary physiologyperi‐procedural myocardial injurypost‐PCI physiologyprecision percutaneous coronary intervention

Autor:innen und Institutionen

  • Department of Interventional Cardiology, Royal Papworth Hospital, Cambridge, UK.
  • Division of Cardiovascular Medicine, University of Cambridge, Cambridge, UK.

ORCID-Profile: Muhammad Aetesam-Ur-Rahman, Joana Oliveira, Bharat Khialani, Stephen P Hoole

Förderung

  • Abbott Vascular
  • Cambridge Biomedical Research Centre
  • Heart and Lung Research Institute

Zitieren

APA

Aetesam-Ur-Rahman, M., Zhao, T. X., Paques, K., Oliveira, J., Chiu, Y. D., Duckworth, M., Khialani, B., Kyranis, S., Bennett, M. R., West, N. E. J., & Hoole, S. P. (2024). Evaluation of microcirculatory protection in percutaneous revascularisation: A stent implantation technique and device comparison. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31155

Vancouver

Aetesam-Ur-Rahman M, Zhao TX, Paques K, Oliveira J, Chiu YD, Duckworth M, et al. Evaluation of microcirculatory protection in percutaneous revascularisation: A stent implantation technique and device comparison. Catheterization and Cardiovascular Interventions. 2024. doi:10.1002/ccd.31155

BibTeX
@article{AetesamUrRahman2024,
  author = {Aetesam-Ur-Rahman, Muhammad and Zhao, Tian X and Paques, Kitty and Oliveira, Joana and Chiu, Yi-Da and Duckworth, Melissa and Khialani, Bharat and Kyranis, Stephen and Bennett, Martin R and West, Nick E J and Hoole, Stephen P},
  title = {Evaluation of microcirculatory protection in percutaneous revascularisation: A stent implantation technique and device comparison},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2024},
  doi = {10.1002/ccd.31155}
}
Kostenlos starten →