EUVIMEDEUVIMED entdecken
Crossref

Development and Validation of a Rapid and Simple LC‐MS/MS Method for Quantification of the Anti‐Microtubule, Anti‐Cancer Agent ABT‐751 in Human and Mouse Plasma and Mouse Tissues

Aristeidis Lentzas, Anna Their, Jos H Beijnen, Mark C de Gooijer iD, Olaf van Tellingen iD

Biomedical Chromatography · 2025

DOI: 10.1002/bmc.70099 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Chromatography, 2025. Verfasst von Aristeidis Lentzas und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Pharmacology, The Netherlands Cancer Institute, Amsterdam, Plesmanlaan, The Netherlands. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Antineoplastic Agents, Sulfonamides. Die Arbeit nennt 18 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A rapid and selective liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was developed and validated for quantifying ABT‐751, an anticancer agent targeting microtubules. Sample preparation involved protein precipitation using acetonitrile and formic acid (100:1, v/v), providing efficient ABT‐751 extraction with minimal ion suppression. Buparlisib (BKM‐120) served as the internal standard. Chromatographic separation was achieved on a Zorbax Extend C18 column, with gradient elution from 20 to 95% methanol in 0.1% (v/v) formic acid in water, and MS/MS detection was performed in positive ionization mode. This assay was validated for human plasma, mouse plasma, and various mouse tissues, including brain, liver, lung, and kidney homogenates. Calibrants were prepared in each respective blank biological matrix, except for mouse tumor tissue, and curves were fitted by quadratic regression from 5 to 10,000 nM. For mouse tumor tissue we used human plasma as surrogate matrix for calibrants. Precision and accuracy for intra‐day and inter‐day measurements were within acceptable limits across low, medium, and high concentrations for all matrices. Stability concerns with ABT‐751 in mouse plasma and tissue homogenate samples that were stored for more than 8 months were identified and addressed. A pilot pharmacokinetic study in mice demonstrated the applicability of this validated LC‐MS/MS method.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryAntineoplastic AgentsSulfonamidesAnimalsMiceHumansChromatography, LiquidReproducibility of ResultsLinear ModelsDrug StabilityLimit of DetectionSensitivity and SpecificityTissue DistributionLiquid Chromatography-Mass Spectrometry

Stichwörter der Autor:innen

ABT‐751 quantitationLC‐MS/MS method validationmouse plasmaprotein precipitationstabilitytissue homogenates

Substanzen

Antineoplastic AgentsABT751Sulfonamides

Autor:innen und Institutionen

  • Division of Pharmacology, The Netherlands Cancer Institute, Amsterdam, Plesmanlaan, The Netherlands.
  • Division of Pharmacoepidemiology and Clinical Pharmacology, Department of Pharmaceutical Sciences, Faculty of Science, Utrecht University, Utrecht, CG, The Netherlands.
  • Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK.
  • The Christie NHS Foundation Trust, Manchester, UK.
  • Mouse Cancer Clinic, The Netherlands Cancer Institute, Amsterdam, The Netherlands.

ORCID-Profile: Mark C de Gooijer, Olaf van Tellingen

Zitieren

APA

Lentzas, A., Their, A., Beijnen, J. H., de Gooijer, M. C., & van Tellingen, O. (2025). Development and Validation of a Rapid and Simple LC‐MS/MS Method for Quantification of the Anti‐Microtubule, Anti‐Cancer Agent ABT‐751 in Human and Mouse Plasma and Mouse Tissues. Biomedical Chromatography. https://doi.org/10.1002/bmc.70099

Vancouver

Lentzas A, Their A, Beijnen JH, de Gooijer MC, van Tellingen O. Development and Validation of a Rapid and Simple LC‐MS/MS Method for Quantification of the Anti‐Microtubule, Anti‐Cancer Agent ABT‐751 in Human and Mouse Plasma and Mouse Tissues. Biomedical Chromatography. 2025. doi:10.1002/bmc.70099

BibTeX
@article{Lentzas2025,
  author = {Lentzas, Aristeidis and Their, Anna and Beijnen, Jos H and de Gooijer, Mark C and van Tellingen, Olaf},
  title = {Development and Validation of a Rapid and Simple LC‐MS/MS Method for Quantification of the Anti‐Microtubule, Anti‐Cancer Agent ABT‐751 in Human and Mouse Plasma and Mouse Tissues},
  journal = {Biomedical Chromatography},
  year = {2025},
  doi = {10.1002/bmc.70099}
}
Kostenlos starten →