Bioprocess in‐line monitoring and control using Raman spectroscopy and Indirect Hard Modeling (IHM)
Biotechnology and Bioengineering · 2024-07 · 121 (7) · 2225-2233
DOI: 10.1002/bit.28724 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biotechnology and Bioengineering, online erschienen am 28.04.2024. Verfasst von David Heinrich Müller und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Technical Thermodynamics, RWTH Aachen University, Aachen, Germany. Hauptthemen laut MEDLINE: Spectrum Analysis, Raman, Saccharomyces cerevisiae, Glucose, Ethanol. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Process in‐line monitoring and control are crucial to optimize the productivity of bioprocesses. A frequently applied Process Analytical Technology (PAT) tool for bioprocess in‐line monitoring is Raman spectroscopy. However, evaluating bioprocess Raman spectra is complex and calibrating state‐of‐the‐art statistical evaluation models is effortful. To overcome this challenge, we developed an Indirect Hard Modeling (IHM) prediction model in a previous study. The combination of Raman spectroscopy and the IHM prediction model enables non‐invasive in‐line monitoring of glucose and ethanol mass fractions during yeast fermentations with significantly less calibration effort than comparable approaches based on statistical models. In this study, we advance this IHM‐based approach and successfully demonstrate that the combination of Raman spectroscopy and IHM is capable of not only bioprocess monitoring but also bioprocess control. For this purpose, we used this combination's in‐line information as input of a simple on–off glucose controller to control the glucose mass fraction in Saccharomyces cerevisiae fermentations. When we performed two of these fermentations with different predefined glucose set points, we achieved similar process control quality as approaches using statistical models, despite considerably smaller calibration effort. Therefore, this study reaffirms that the combination of Raman spectroscopy and IHM is a powerful PAT tool for bioprocesses.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute of Technical Thermodynamics, RWTH Aachen University, Aachen, Germany.
Zitieren
APA
Müller, D. H., Börger, M., Thien, J., & Koß, H. J. (2024). Bioprocess in‐line monitoring and control using Raman spectroscopy and Indirect Hard Modeling (IHM). Biotechnology and Bioengineering, 121(7), 2225-2233. https://doi.org/10.1002/bit.28724
Vancouver
Müller DH, Börger M, Thien J, Koß HJ. Bioprocess in‐line monitoring and control using Raman spectroscopy and Indirect Hard Modeling (IHM). Biotechnology and Bioengineering. 2024;121(7):2225-2233. doi:10.1002/bit.28724
BibTeX
@article{Mller2024,
author = {Müller, David Heinrich and Börger, Marieke and Thien, Julia and Koß, Hans-Jürgen},
title = {Bioprocess in‐line monitoring and control using Raman spectroscopy and Indirect Hard Modeling (IHM)},
journal = {Biotechnology and Bioengineering},
year = {2024},
volume = {121},
number = {7},
pages = {2225--2233},
doi = {10.1002/bit.28724}
}
EUVIMED