EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Editorial Commentary : What Happens in the Knee Doesn't Always Stay in the Knee: Systemic Effects of Vancomycin‐Soaked Anterior Cruciate Ligament Grafts

Mark G. Siegel

Arthroscopy · 2026-11-09

DOI: 10.1002/arj.70791 ↗
AbstractBibliografische Angaben

Abstract

Abstract Medications introduced into the knee cavity will be absorbed systemically over time. Additionally, presoaking anterior cruciate ligament grafts in vancomycin has become standard practice for most surgeons before implanting the graft. Because vancomycin can cause ototoxicity and nephrotoxicity above certain levels, there is a concern about the additional systemic load of an antibiotic‐soaked graft. An analysis of systemic levels after implanting a vancomycin graft indicates that it can be done safely and with low risk of systemic toxicity.