EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Evaluating ADR , APC , and APP in screening and surveillance colonoscopies: Impact of age, procedure volume, and operator experience

Lee‐Won Chong, Tsan‐Hsuan Chang, Hung‐Chuen Chang, Yu‐Hwa Liu, Cheuk‐Kay Sun, Kou‐Ching Yang, Yu‐Min Lin

Advances in Digestive Medicine · 2026-09 · 13 (3)

DOI: 10.1002/aid2.70036 ↗
AbstractBibliografische Angaben

Abstract

Abstract Adenoma detection rate (ADR) is a key quality indicator for colonoscopy but is limited by the “one‐and‐done” phenomenon. A multimetrics approach may provide a more comprehensive assessment of detection quality. To evaluate the correlations between ADR, adenomas per colonoscopy (APC), and adenomas per positive colonoscopy (APP), and to identify factors influencing detection quality. This retrospective study analyzed screening and surveillance colonoscopies performed during health checkups from 2014 to 2020 at a medical center in Taiwan. ADR, APC, and APP were evaluated according to patient age (70 years), colonoscopy volume (total number of procedures per operator), and operator experience (junior: 10 years). Statistical analyses included ANOVA, linear regression, and Pearson's correlation coefficient (r), with p < .05 considered statistically significant. A total of 33 064 colonoscopies were performed by 21 endoscopists (9 senior, 4 mid‐level, and 8 junior) during the study period. The mean age of the patients was 49 years. The overall ADR was 29.1%, APC was 0.46, and APP was 1.57. Significant positive correlations were observed between ADR and APC ( r = 0.96), APC and APP ( r = 0.83), and ADR and APP ( r = 0.64) (all p < .01). ADR, APC, and APP increased significantly with patient age ( p < .01). Colonoscopy volume was negatively correlated with ADR ( r = −0.68, p < .01), APC ( r = −0.64, p < .01), and APP ( r = −0.42, p = .03). Junior operators demonstrated significantly higher ADR (38.6%, p < .01) and APC (0.66, p = .01) compared to senior operators. APP was also higher among junior operators (1.72) but did not reach statistical significance ( p = .11). ADR, APC, and APP are significantly correlated. Multimetrics assessment may complement ADR by addressing the one‐and‐done effect. Detection quality is influenced by patient age, operator experience, and workload, highlighting the need for continuous training and quality assurance.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →