Geometric distortion in computed tomography scans for radiotherapy: Quantification and quality assurance implications

Yunfei Hu, Emma Cai, John Shakeshaft, Marius Arnesen, Tina Gorjiara, Mikel Byrne, Tim Markwell, Ben Archidbald‐Heeren

Journal of Applied Clinical Medical Physics · 2026-07 · 27 (7)

DOI: 10.1002/acm2.70686 ↗
AbstractBibliografische Angaben

Abstract

Abstract Background Computed tomography (CT) is widely assumed to be geometrically accurate and is commonly used as the reference standard for quantifying geometric distortion in other imaging modalities, particularly magnetic resonance imaging (MRI). However, geometric distortion in CT has not been comprehensively investigated. Purpose The aim of this study was to characterize the performance of a distortion phantom, establish a reference scan and, on this basis, determine and quantify the presence of geometric distortion in CT scans used for radiotherapy (RT) planning. Methods A CIRS Model 603A Distortion Phantom was employed to quantify geometric distortion. System reproducibility, as well as the effects of phantom setup, scan parameters, fabrication uncertainty, and temporal variation were systematically evaluated. Additionally, the geometric distortion of CT was compared to that of linac‐based cone‐beam CT (CBCT). Subsequently, geometric distortion magnitudes from eight CT scanners were retrospectively analyzed against both CBCT and a Computer Aided Design (CAD) model. Results CBCT demonstrated consistently smaller distortion variation compared with CT. Retrospective analysis revealed that all eight analyzed CT scanners exhibited measurable distortion magnitudes, with mean magnitudes ranging from 0.13 mm to 0.52 mm and maximum distortion magnitudes ranging from 0.45 mm to 1.09 mm when compared to CBCT, or 0.25 mm to 0.82 mm and 0.58 mm to 1.88 mm when compared to the CAD model. Longitudinal couch inaccuracy or non‐linear couch sag may constitute the primary contributors to geometric distortion on CT scanners. Conclusions Contrary to common assumptions, CT scans used for radiotherapy planning exhibit measurable geometric distortion across clinically relevant fields of view (FoVs). However, current CT QA methodologies and tolerances may lack sufficient sensitivity to detect submillimeter distortion levels relevant to stereotactic radiotherapy (SRT). Recognition and rigorous quantification of CT geometric distortion are essential to inform risk assessment and margin design in high‐precision RT.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →