Cumulative dose assessment with transformer‐based deformable image registration addition for cervical cancer patients
Journal of Applied Clinical Medical Physics · 2025
DOI: 10.1002/acm2.70135 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Dongdong Zhou und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Shanghai Key Laboratory of Maternal Fetal Medicine, Shanghai Institute of Maternal-Fetal Medicine and Gynecologic Oncology, Shanghai Fi…. Hauptthemen laut MEDLINE: Uterine Cervical Neoplasms, Radiotherapy Planning, Computer-Assisted, Organs at Risk, Brachytherapy. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Innovation Plan Of Shanghai Science and Technology Commission, Pudong District Obstetrics and Gynecology Medical Association Project, National Natural Science Foundation of China.
Themen: Onkologische Pflege
Abstract (Originalsprache)
Purpose
Based on the combination mode of internal and external radiotherapy for cervical cancer, this study aimed to investigate an accurate transformer‐based deformable image registration (DIR) method for cumulative dose assessment. Methods and Materials According to a retrospective analysis conducted on 180 patients with cervical cancer who underwent intracavitary brachytherapy (ICBT) and external beam radiation therapy (EBRT), this study proposed a mix‐transformer structure‐based deformable image registration (MTDIR) network for registering CT scans of ICBT and EBRT, followed by dose accumulation and assessment. The mean dice similarity coefficient (DSC) and Hausdorff distance (HD) of the rectum and bladder were computed to compare the performance of MTDIR with that of the state‐of‐the‐art VoxelMorph method and the DIR method provided by velocity. Additionally, the cumulative dose of the bladder and rectum from four methods was calculated: direct DVH parameter addition (DA), DIR‐based dose addition provided by Velocity (VA), VoxelMorph‐based dose addition (VoA), and MTDIR‐based dose addition (MA).
Results
The mean DSC values of MTDIR, VoxelMorph, and Velocity for the bladder were 0.78, 0.75, and 0.72 for the registration between CT scans of EBRT and the last ICBT, respectively. The mean DSC values of the rectum were also equal to 0.58, 0.56, and 0.52. The mean HDmean values of MTDIR, VoxelMorph, and Velocity for the bladder were 4.81, 5.16, and 5.43, and the mean HDmean values of the rectum were 5.41, 5.81, and 6.93, respectively. For the registration between CT scans of ICBT, the mean DSC values of MTDIR, VoxelMorph, and Velocity for the bladder were obtained 0.82, 0.80, and 0.77, and the mean DSC values for the rectum were equal to 0.70, 0.68, and 0.63, respectively. The mean HDmean values of MTDIR, VoxelMorph, and Velocity for the bladder were 4.22, 4.58, and 4.79, and the mean HDmean values of the rectum were obtained 4.86, 5.17, and 5.64, respectively. The results generally suggested that MTDIR outperformed VoxelMorph and Velocity.
Conclusions
The study findings demonstrated that the model developed based on parameters obtained from the proposed method exhibited higher registration accuracy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Shanghai Key Laboratory of Maternal Fetal Medicine, Shanghai Institute of Maternal-Fetal Medicine and Gynecologic Oncology, Shanghai First Maternity and Infant Hospital, School of Medicine, Tongji Universi…
- Department of Nantong University Xinglin College, Nantong, China.
- Department of School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China.
- Department of MedMind Technology Co., Ltd., Beijing, China.
Förderung
- Science and Technology Innovation Plan Of Shanghai Science and Technology Commission
- Pudong District Obstetrics and Gynecology Medical Association Project
- National Natural Science Foundation of China
- Talent Pool Project of Shanghai First Maternity and Infant Hospital
Zitieren
APA
Zhou, D., Shao, Y., Wan, F., Chen, J., Zhang, Y., Feng, J., Ye, Y., Zhou, J., Zeng, F., Chen, Q., Wang, S., Lu, H., & Yang, L. (2025). Cumulative dose assessment with transformer‐based deformable image registration addition for cervical cancer patients. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70135
Vancouver
Zhou D, Shao Y, Wan F, Chen J, Zhang Y, Feng J, et al. Cumulative dose assessment with transformer‐based deformable image registration addition for cervical cancer patients. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70135
BibTeX
@article{Zhou2025,
author = {Zhou, Dongdong and Shao, Yuheng and Wan, Fuying and Chen, Jiayi and Zhang, Yumeng and Feng, Jiaqi and Ye, Yunfei and Zhou, Jinglan and Zeng, Fubin and Chen, Qi and Wang, Shaobin and Lu, Heqing and Yang, Liang},
title = {Cumulative dose assessment with transformer‐based deformable image registration addition for cervical cancer patients},
journal = {Journal of Applied Clinical Medical Physics},
year = {2025},
doi = {10.1002/acm2.70135}
}
EUVIMED