EUVIMEDDécouvrir EUVIMED
CrossrefCarte d’information

Reliability and accuracy of smartphone-based facial scanning: Validation with direct anthropometry

Prakash C, Pradeep Kandikatla, Anoosha Manda, Praveen Kumar Varma, Nagisetti Hari Babu, Avichal Singh Sodhi

Journal of Orthodontics · 2026-11-03

DOI: 10.1177/14653125261498916 ↗
RésuméRéférences bibliographiques

Résumé

Objectives: To evaluate the reliability and measurement agreement of two smartphone-based facial scanning applications—Qlone (iOS) and Magiscan (Android)—with direct anthropometry following scale factor calibration, and to assess intra- and inter-examiner reliability. Methods: A total of 22 orthodontic patients were enrolled in this prospective study. Nine soft tissue landmarks (midsagittal and bilateral) were marked using 2.5 mm stickers and three vertical and six transverse linear distances were measured using digital vernier calliper (resolution 0.01 mm, accuracy ±0.02 mm) for direct anthropometry and MeshLab software following .obj export and scaling for both applications. Reliability was assessed in 10 randomly selected patients after 15 days. Results: Repeated-measures ANOVA (F-statistic, 2 and 42 degrees of freedom) showed no statistically significant differences between Qlone, Magiscan, and direct anthropometry for 8/9 parameters (p range 0.165–0.988; η 2 p range 0.001–0.082). A statistically significant difference was found for Exo Left–N (p = 0.041; η 2 p = 0.141; mean difference 0.55 mm), not considered clinically significant. Bland–Altman analysis confirmed clinically acceptable agreement (mean bias ⩽ 0.55 mm across all comparisons). Intraclass correlation coefficients (two-way mixed model, absolute agreement) were excellent for all parameters (intra-examiner 0.998–1.000, inter-examiner 0.994–0.999), with relative TEM ⩽ 0.79% and reliability coefficient R ⩾ 0.994. Conclusion: Following scale factor calibration, smartphone-based 3D facial scanning application demonstrate high reliability, precision, and clinically acceptable agreement with direct anthropometry. These applications offer a portable and cost-effective option for facial assessment in orthodontic practice, pending independent accuracy validation using a non-circular reference standard.

Des connaissances adaptées à votre travail.

D’un démarrage gratuit à la Research Suite complète, en passant par la recherche bibliographique personnelle.

Voir les tarifs →

Tous les textes intégraux sont-ils inclus ?

Non. Notices, résumés et textes intégraux sont des contenus distincts. La disponibilité dépend de la source, de l’accès ouvert et de vos licences. Une offre EUVIMED ne remplace pas des droits supplémentaires auprès des éditeurs.

Voir les tarifs →