EUVIMEDObjevte EUVIMED
CrossrefInformační karta

Bachmann Bundle Pacing and Acute Changes in Left Atrial Mechanical Function in Patients With Interatrial Block: A Within‐Subject Echocardiography Analysis

Xiahenazi Aiyasiding, Jiandu Yang, Qinglong Meng, Zhongli Chen, Mengxing Cai, Yuzhu Chen, Xiaojian Chi, Xueqi Wan, Chongqiang Li, Wei Wang, Yan Dai, Keping Chen

Journal of Cardiovascular Electrophysiology · 2026-11-03

DOI: 10.1111/jce.70547 ↗
AbstraktBibliografické údaje

Abstrakt

ABSTRACT Background Interatrial block (IAB) is associated with atrial electromechanical dysfunction and adverse cardiovascular outcomes. Bachmann bundle pacing (BBP) has emerged as a physiological atrial pacing strategy capable of restoring interatrial conduction synchrony. However, its impact on left atrial (LA) mechanical function and hemodynamics remains unclear. Objective To evaluate the acute effects of BBP on atrial mechanical parameters in patients with IAB. Methods In this prospective single‐center study, 31 patients with IAB who underwent successful BBP implantation were enrolled. A standardized postoperative evaluation protocol was performed under intrinsic sinus rhythm (SR), right atrial septal pacing (RASP) at atrial lead threshold +0.5 V/0.4 ms, and BBP at 5 V/0.4 ms using a within‐subject repeated‐measures design. Electrocardiographic and echocardiographic parameters were analyzed using linear mixed‐effects models, with additional adjustment for heart rate. Results BBP produced significantly greater P wave duration (PWD) shortening than RASP ( p < 0.001). Compared with SR, BBP was associated with lower LA volume indices and higher LA emptying fraction and LA expansion index (all p < 0.001), with consistent superiority over RASP at acute postoperative phase. These associations remained significant after heart rate adjustment. The observed acute changes were consistent across partial and advanced IAB subgroups without significant interaction effects. Conclusions In patients with IAB, electrical resynchronization during BBP was accompanied by acute changes in LA mechanical parameters compared with SR and RASP. These findings suggest that BBP may represent a promising physiological pacing strategy for patients with atrial conduction disease.

Znalosti, které odpovídají vaší práci.

Od bezplatného začátku přes osobní rešerše literatury až po kompletní Research Suite.

Zobrazit tarify →

Jsou zahrnuty všechny plné texty vydavatelů?

Ne. Bibliografické záznamy, abstrakty a plné texty jsou různé typy obsahu. To, zda je plný text dostupný, závisí na zdroji, Open Access a vašich stávajících licencích. Tarif EUVIMED nenahrazuje dodatečná vydavatelská práva.

Zobrazit tarify →