EUVIMEDΑνακαλύψτε το EUVIMED
CrossrefΚάρτα πληροφοριών

Open-source, high-speed and high-resolution data acquisition platform for biopotential recordings and neural EIT applications

Enrico Ravagli, Alistair McEwan, Kirill Aristovich

Physiological Measurement · 2026-11-30 · 47 (11) · 115002

DOI: 10.1088/1361-6579/aeb9a0 ↗
ΠερίληψηΒιβλιογραφικά στοιχεία

Περίληψη

Abstract Objective. Biopotential measurement devices, such as electroencephalography, electrocardiography (ECG), and electromyography (EMG) recorders, are available in low-cost, open-source implementations with standard specifications. However, high-end systems remain expensive and predominantly proprietary, limiting accessibility and customization by research laboratories. In addition, neurophysiology techniques such as bioimpedance-based fast neural electrical impedance tomography (FN-EIT) also rely on these systems for data acquisition. This work aimed to develop an open-source biopotential recording system using off-the-shelf components that achieves performance comparable to high-end devices. Approach. We designed our system to provide simultaneous sampling over 32 channels, 24-bit resolution, 10 kHz bandwidth, 50 kHz sampling rate, and battery-powered operation while reducing cost by two orders of magnitude. System performance was evaluated comparatively against a reference device. Initial validation involved benchtop recordings in saline solution and standard non-invasive biopotential measurements (ECG and EMG). Further in-vivo validation was performed by recording evoked electrophysiological responses and FN-EIT traces from the sciatic nerve of a rat during tibial branch stimulation. Main results. EMG recordings showed comparable RMS peak amplitudes (814 ± 153 µ V vs 897 ± 113 µ V, p = 0.07), while ECG-derived heart rates closely matched between systems (64.8 ± 4.0 bpm vs 65.1 ± 3.1 bpm, p = 0.54). During in-vivo recordings, compound action potentials exhibited comparable amplitudes and morphology (129 ± 26 mV vs 128 ± 25 mV, P = 0.15). FN-EIT recordings showed strongly correlated baseline voltages ( R > 0.93, P = 0.11), sub-microvolt noise levels (0.83 ± 0.36 µ V vs 0.42 ± 0.25 µ V, p < 0.05), and comparable impedance variations (0.006 ± 0.002% vs 0.005 ± 0.003, P > 0.05). FN-EIT images of functional activity recorded with the novel device closely matched reference ones, exhibiting a 98.5% overlap in activated area. Significance. The proposed open-source device has the potential to broaden research access to customizable, high-specification data acquisition hardware and facilitate wider adoption of specialized neural recording techniques such as FN-EIT.

Γνώση που ταιριάζει στην εργασία σας.

Από το δωρεάν ξεκίνημα και την προσωπική βιβλιογραφική έρευνα έως το πλήρες Research Suite.

Προβολή τιμολογίων →

Περιλαμβάνονται όλα τα πλήρη κείμενα εκδοτών;

Όχι. Οι βιβλιογραφικές καταχωρίσεις, οι περιλήψεις και τα πλήρη κείμενα είναι διαφορετικά περιεχόμενα. Το αν είναι διαθέσιμο ένα πλήρες κείμενο εξαρτάται από την πηγή, το Open Access και τις υπάρχουσες άδειές σας. Ένα πακέτο EUVIMED δεν υποκαθιστά πρόσθετα δικαιώματα εκδοτών.

Προβολή τιμολογίων →